EASYPHACO® TECHNOLOGY in cataract surgery
The easyPhaco technology was developed for safe and efficient phacoemulsification. The high vacuum setting and the wide infusion path of the easyTips create a direct flow to the tip. This results in a magnet-like attraction of the fragments *. The angled easyTip opening has been designed to hold fragments firmly at the tip *. Thanks to the strong holdability and the longitudinal movements of the easyTips, ultrasound is directed axially to the occluded fragments. Following an occlusion break, the capillary aspiration path of the easyTips provides continuous aspiration. Thanks to the high vacuum created, the fragments are efficiently aspirated *. The infusion capacity is several times higher than the aspiration, enabling the intraocular pressure to be maintained for a stable anterior chamber 1.
easyPhaco handpiece
Phaco Handpiece | |
---|---|
VG800011 | easyPhaco handpiece, reusable |
Titanium easyTips
Titanium easyTip disposable |
|
---|---|
VV806833A | Phaco tip easyTip CO-MICS, 30°, for incisions of 1.6-1.8 mm |
VV806833 | Phaco tip easyTip CO-MICS, 53°, for incisions of 1.6-1.8 mm |
VV806835B | Phaco tip easyTip 2.2 mm, 15°, for incisions of 2.2-2.4 mm |
VV806835A | Phaco tip easyTip 2.2 mm, 30°, for incisions of 2.2-2.4 mm |
VV806835 | Phaco tip easyTip 2.2 mm, 40°, for incisions of 2.2-2.4 mm |
VV806840 | Phaco tip easyTip 2.8 mm, 30°, for incisions of 2.8-3.2 mm |
easyTip disposable: Box of 10 with irrigation sleeve, test chamber, phaco key and emergency key.
Titanium easyTip reusable |
|
---|---|
VV800831 | Phaco tip easyTip CO-MICS, 30°, for incisions of 1.6-1.8 mm |
VV800833 | Phaco tip easyTip CO-MICS, 53°, for incisions of 1.6-1.8 mm |
VV603231 | Irrigation sleeve for incisions of 1.6-1.8 mm, silicone, grey |
VV800735B | Phaco tip easyTip 2.2 mm, 15°, for incisions of 2.2-2.4 mm |
VV800735A | Phaco tip easyTip 2.2 mm, 30°, for incisions of 2.2-2.4 mm |
VV800735 | Phaco tip easyTip 2.2 mm, 40°, for incisions of 2.2-2.4 mm |
VV603220 | Irrigation sleeve for incisions of 2.2-2.4 mm, silicone, transparent |
VV800740 | Phaco tip easyTip 2.8 mm, 30°, for incisions of 2.8-3.2 mm |
VV603209 | Irrigation sleeve for incisions of 2.8-3.2 mm, silicone, blue |
Discover the whole range now
Advantages of easyPhaco®
- easyPhaco technology, developed for safe and efficient emulsification
- Fragment followability and holdability thanks to the Oertli fluidics concept *
- U/S energy absorbed by the occluded fragments
- Smooth fragment aspiration without clogging *
- Stable anterior chamber 1
- Available from 1.6 mm to 3.2 mm incisions
Recommended settings for easyPhaco
The Oertli easyPhaco technology is available in three different tip sizes. Incisions of sub–2-mm coaxial micro-phaco up to standard incision sizes of up to 3.2 mm can be used with easyPhaco.
Minimum | Venturi pump | Peristaltic pump / SPEEP pump | |||
Vacuum (mmHg) | Vacuum effect (%) | Flow (ml/min) | Vacuum (mmHg) | ||
easyTip CO-MICS for incisions of 1.6-1.8 mm |
Phaco 1 (Grooving) Phaco 2 |
80 250 |
60 60 |
18 20 |
50 250 |
easyTip 2.2 mm for incisions of 2.2-2.4 mm |
Phaco 1 (Grooving) Phaco 2 |
80 400 |
60 60 |
18 40 |
50 400 |
easyTip 2.8 mm for incisions of 2.8-3.2 mm |
Phaco 1 (Grooving) Phaco 2 |
80 400 |
60 60 |
18 40 |
50 400 |
--> Recommended bottle height: 100 cm above the patient eye
--> Recommended additional settings: Pulse mode, 40 Hz, 60% cooling for Phaco 2.
easyPhaco is a development from Oertli R&D in scientific collaboration with Professor Rupert Menapace, Vienna.
Please contact your sales partner to determine your optimal easyPhaco values.
Win insights on easyPhaco now
Do you want to find out more about it?
-
Advantages of CO-MICS with easyTip, CRST Europe, Prof. Daniel Mojon, 2021
-
The Power of Physics and Fluidics, The Ophthalmologist, Armin Wolf, 2021
-
How Physics and Fluidics Bring Modern Cataract Surgery to the Next Level, CRST Europe, Armin Wolf, 2020
-
The Future Way of Phaco & MIGS Surgeries – Highlights from ESCRS Satellite Symposium, The Ophthalmologist, 2015
-
easyPhaco Technology, Dr. Aguilera, Highlights of Ophthalmology, 2012
-
A comparative study proves the higher efficacy and safety of easyPhaco, Ophthalmology Times Europe, 2013
-
easyPhaco - A quantum leap, Prof. Arnd Gandorfer, European Ophthalmic Review, 2010
-
Updates in Cataract Surgery, Ocular Surgery News, 2011